Strain in GaAs by low-dose ion implantation
- 15 February 1987
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 61 (4) , 1335-1339
- https://doi.org/10.1063/1.338112
Abstract
The production of strain in (100) GaAs by low-dose ion implantation has been investigated. Implantations were conducted at room temperature with ions of He, B, C, Ne, Si, P, and Te. Energies were between 100 and 500 keV, and each species was implanted over a range of doses sufficient to create perpendicular strain below 0.3%. The perpendicular strains ε ⊥ were measured by x-ray double-crystal diffractometry about the (400) Bragg condition. Detailed depth profiles of ε⊥ were obtained by fitting the resulting rocking curves with a kinematic model for the diffraction. For all implantations the maximum in the ε⊥ distribution was found approximately from the separation of the lowest-angle prominent oscillation from the substrate peak. The depth profiles of perpendicular strain had the same shape as the calculated profiles of energy deposited per ion by nuclear collisions, FD. The maximum perpendicular strains scaled linearly with the dose φ of the implanted ions for all ion species. Also the ratio of maximum strain to dose was found to vary linearly with FD over more than 2 orders of magnitude in FD. We therefore conclude that ε⊥=KφFD at all depths, where K is a constant. The value of K was found to be (5±1)×10−2 Å3/eV. Our results suggest that this holds for any ion species in the mass range 4–128 amu, with energy in the hundreds of keV, implanted into (100) GaAs at room temperature, provided the maximum strain is less than 0.3%.This publication has 12 references indexed in Scilit:
- MeV ion damage in GaAs single crystals: Strain saturation and role of nuclear and electronic collisions in defect productionPhysical Review B, 1986
- Characterization of Lattice Damage in Ion Implanted Silicon: Monte Carlo Simulation Combined with Double Crystal X-Ray DiffractionPhysica Status Solidi (a), 1985
- Damage Profiles in Ion Implanted SiliconPhysica Status Solidi (a), 1984
- Strain/Damage in Crystalline Materials Bombarded by MeV Ions: Recrystallization of GaAs by High-Dose IrradiationMRS Proceedings, 1984
- Pearson distributions for ion rangesApplied Physics Letters, 1983
- X-ray rocking curve study of Si-implanted GaAs, Si, and GeApplied Physics Letters, 1982
- Kinematical x-ray diffraction in nonuniform crystalline films: Strain and damage distributions in ion-implanted garnetsJournal of Applied Physics, 1981
- Modelling strain distributions in ion-implanted magnetic bubble materialsJournal of Applied Physics, 1981
- Strain profiles in ion-doped silicon obtained from X-ray rocking curvesPhysica Status Solidi (a), 1980
- Unidirectional contraction in boron-implanted laser-annealed siliconApplied Physics Letters, 1978