Methods for beam data acquisition offered by a mini-phantom
- 1 January 1999
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (4) , 817-832
- https://doi.org/10.1088/0031-9155/44/4/001
Abstract
Mini-phantoms are an important tool for measurement of basic head scatter parameters in high-energy photon beams, and recently they have also been used for beam quality specification. Therefore the feasibility and reliability of basic beam parameter acquisition using only a mini-phantom is checked in 6, 18 and 25 MV photon beams. These parameters include head scatter correction factors, phantom scatter correction factors, total scatter correction factors, wedge factors, off-axis ratios, as well as beam attenuation coefficients and beam hardening coefficients. In order to specify beam quality variations and beam quality modifications by a wedge, two different methods are compared: the first method uses a constant source to chamber distance of 1 m, the second method refers to narrow beam geometry. Mu values derived with two different beam quality specification methods show a systematic deviation. However, relative variations of the attenuation coefficient within the beam and the associated beam quality modifications observed with the two methods show good agreement in open and wedged beams. Phantom scatter correction factors are calculated from measured head scatter correction factors and total scatter correction factors as well as from attenuation coefficients. Measured and calculated phantom scatter correction factors agree within 1% with the values given in literature. For 18 and 25 MV photon beam, wedge factors measured in water or in the mini-phantom agree within 0.5%, but maximum deviations of approximately 1.5% are observed at 6 MV for the largest field sizes. It is demonstrated that the determination of several beam data related to full scatter conditions does not necessarily require the availability of a full scatter phantom. The mini-phantom is a reliable but very cheap and simple tool. It offers versatile possibilities to measure, check and verify basic beam parameters in high-energy photon beams.Keywords
This publication has 24 references indexed in Scilit:
- Relations between scatter factor, quality index and attenuation for x-ray beamsPhysics in Medicine & Biology, 1998
- Output ratios in a miniphantom for asymmetric fields shaped by a multileaf collimatorPhysics in Medicine & Biology, 1997
- Measurements of basic parameters in wedged high-energy photon beams using a mini-phantomPhysics in Medicine & Biology, 1997
- Quality control of measured x-ray beam dataMedical Physics, 1997
- Intercomparison of normalized head-scatter factor measurement techniquesMedical Physics, 1995
- Attenuation in high‐energy x‐ray beamsMedical Physics, 1994
- The relation between wedge factors in air and waterMedical Physics, 1994
- Calculation and Application of Point Spread Functions for Treatment Planning with High Energy Photon BeamsActa Oncologica, 1987
- On the use of a quality index to specify high energy photon beamsRadiotherapy and Oncology, 1986
- Off-axis beam quality change in linear accelerator x-ray beamsMedical Physics, 1980