Atrioesophageal fistula is an uncommon but often lethal complication of atrial fibrillation (AF) ablation. The purpose of our study was to prospectively investigate the incidence of esophageal ulcerations (ESUL) as well as the impact of energy settings, radiofrequency lesion sets, and direct visualization of the esophagus on esophageal wall injury. One hundred seventy-five patients, 57.1% paroxysmal AF, 78.5% male, underwent AF ablation and esophagoscopy 24 hours thereafter. We performed a 2:1:1-randomization as follows: Ablation without visualization of the esophagus using 25 Watt (W) power limit on the posterior wall, n = 70. Visualization and 15 W maximum: Ablation guided by barium visualization of the esophageal course using a limit of 15 W, n = 35. Visualization and 25 W "short burns": Ablation guided by barium visualization using 25 W and "short burns" (max. 5 sec), n = 35. Patients performed under general anesthesia (n = 35) were separated as a nasogastric tube for visualization of the esophagus was used. In total, we found 2.9% of patients (5/175) presenting ESUL. Parameters discriminating the development of ESUL in a specific patient were type of AF, maximum energy delivered, usage of a nasogastric tube, and additional left atrial lines. Visualization of the esophageal course by barium contrast was not able to prevent ESUL. ESUL is a rare finding when using a reasonable energy maximum of 25 W with open-irrigated tip catheters at the posterior wall. Lower energy settings may increase safety without losing efficacy. Additional linear radiofrequency lesions increase the risk of ESUL development.Keywords
This publication has 25 references indexed in Scilit:
- Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillationEP Europace, 2008
- Pain and Anatomical Locations of Radiofrequency Ablation as Predictors of Esophageal Temperature Rise During Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2007
- Impact of Integration of Multislice Computed Tomography Imaging into Three‐Dimensional Electroanatomic Mapping on Clinical Outcomes, Safety, and Efficacy Using Radiofrequency Ablation for Atrial FibrillationPacing and Clinical Electrophysiology, 2007
- Randomized Comparison Between Open Irrigation Technology and Intracardiac‐Echo‐Guided Energy Delivery for Pulmonary Vein Antrum Isolation: Procedural Parameters, Outcomes, and the Effect on Esophageal InjuryJournal of Cardiovascular Electrophysiology, 2007
- Randomized Comparison Between Open Irrigation Technology and Intracardiac‐Echo‐Guided Energy Delivery for Pulmonary Vein Antrum Isolation: Procedural Parameters, Outcomes, and the Effect on Esophageal InjuryJournal of Cardiovascular Electrophysiology, 2007
- Atrial Fibrillation Ablation with Esophageal Cooling with a Cooled Water‐Irrigated Intraesophageal Balloon: A Pilot StudyJournal of Cardiovascular Electrophysiology, 2006
- Comparison of Cool Tip Versus 8‐mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long‐Term Control of Atrial Fibrillation: A Prospective Randomized Pilot StudyJournal of Cardiovascular Electrophysiology, 2006
- Real‐Time Monitoring of Luminal Esophageal Temperature During Left Atrial Radiofrequency Catheter Ablation for Atrial Fibrillation: Observations About Esophageal Heating During Ablation at the Pulmonary Vein Ostia and Posterior Left AtriumJournal of Cardiovascular Electrophysiology, 2006
- Comparison Between Anatomical and Integrated Approaches to Atrial Fibrillation Ablation: Adjunctive Role of Electrical Pulmonary Vein DisconnectionJournal of Cardiovascular Electrophysiology, 2005
- Diagnosis of Esophagogastric TumorsEndoscopy, 2005