Multiple Ionization Mass Spectrometry Strategy Used To Reveal the Complexity of Metabolomics
- 18 December 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (2) , 421-429
- https://doi.org/10.1021/ac701982e
Abstract
A multiple ionization mass spectrometry strategy is presented based on the analysis of human serum extracts. Chromatographic separation was interfaced inline with the atmospheric pressure ionization techniques electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (+) and negative (−) ionization modes. Furthermore, surface-based matrix-assisted laser desorption/ionization (MALDI) and desorption ionization on silicon (DIOS) mass spectrometry were also integrated with the separation through fraction collection and offline mass spectrometry. Processing of raw data using the XCMS software resulted in time-aligned ion features, which are defined as a unique m/z at a unique retention time. The ion feature lists obtained through LC−MS with ESI and APCI interfaces in both ± ionization modes were compared, and unique ion tables were generated. Nonredundant, unique ion features, were defined as mass numbers for which no mass numbers corresponding to [M + H]+, [M − H]-, or [M + Na]+ were observed in the other ionization methods at the same retention time. Analysis of the extracted serum using ESI for both (+) and (−) ions resulted in >90% additional unique ions being detected in the (−) ESI mode. Complementing the ESI analysis with APCI resulted in an additional ∼20% increase in unique ions. Finally, ESI/APCI ionization was combined with fraction collection and offline-MALDI and DIOS mass spectrometry. The parts of the total ion current chromatograms in the LC−MS acquired data corresponding to collected fractions were summed, and m/z lists were compiled and compared to the m/z lists obtained from the DIOS/MALDI spectra. It was observed that, for each fraction, DIOS accounted for ∼50% of the unique ions detected. These results suggest that true global metabolomics will require multiple ionization technologies to address the inherent metabolite diversity and therefore the complexity in and of metabolomics studies.Keywords
This publication has 23 references indexed in Scilit:
- Current challenges and developments in GC–MS based metabolite profiling technologyJournal of Biotechnology, 2006
- PRIMARY BIOMARKERS IN CEREBRAL SPINAL FLUID OBTAINED FROM PATIENTS WITH INFLUENZA-ASSOCIATED ENCEPHALOPATHY ANALYZED BY METABOLOMICSInternational Journal of Neuroscience, 2006
- Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MSJournal of Experimental Botany, 2004
- Unexpected observation of ion suppression in a liquid chromatography/atmospheric pressure chemical ionization mass spectrometric bioanalytical methodRapid Communications in Mass Spectrometry, 2004
- Derivatization for LC-Electrospray Ionization-MS: A Tool for Improving Reversed-Phase Separation and ESI Responses of Bases, Ribosides, and Intact NucleotidesAnalytical Chemistry, 2004
- The contributions of specific amino acid side chains to signal intensities of peptides in matrix‐assisted laser desorption/ionization mass spectrometryRapid Communications in Mass Spectrometry, 2004
- A Strategy for Identifying Differences in Large Series of Metabolomic Samples Analyzed by GC/MSAnalytical Chemistry, 2004
- Monolithic Silica-Based Capillary Reversed-Phase Liquid Chromatography/Electrospray Mass Spectrometry for Plant MetabolomicsAnalytical Chemistry, 2003
- Combined Electrospray Ionization−Atmospheric Pressure Chemical Ionization Source for Use in High-Throughput LC−MS ApplicationsAnalytical Chemistry, 2003
- Nontargeted Metabolome Analysis by Use of Fourier Transform Ion Cyclotron Mass SpectrometryOMICS: A Journal of Integrative Biology, 2002