Laser Doppler velocimetry (LDV) and 3D phase‐contrast magnetic resonance angiography (PC‐MRA) velocity measurements: Validation in an anatomically accurate cerebral artery aneurysm model with steady flow
- 29 October 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1493-1505
- https://doi.org/10.1002/jmri.21179
Abstract
Purpose To verify the accuracy of velocity mapping with three‐dimensional (3D) phase‐contrast magnetic resonance angiography (PC‐MRA) for steady flow in a realistic model of a cerebral artery aneurysm at a 3T scanner. Materials and Methods Steady flow through an original geometry model of a cerebral aneurysm was mapped at characteristic positions by state‐of‐the‐art laser Doppler velocimetry (LDV) as well as 3D PC‐MRA at 3T. The spatial distributions and local values of two velocity components obtained with these two measurement methods were compared. Results The 3D PC‐MRA velocity field distribution and mean velocity values exhibited only minor differences to compare to the LDV measurements in straight artery regions for both main and secondary velocities. The differences increased in regions with disturbed flow and in cases where the measurement plane was not perpendicular to the main flow direction. Conclusion 3D PC‐MRA can provide reliable measurements of velocity components of steady flow in small arteries. The accuracy of such measurements depends on the artery size and the measurement plane positioning. J. Magn. Reson. Imaging 2007.Keywords
This publication has 27 references indexed in Scilit:
- Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging: feasibility study based on a geometrically realistic in vitro aneurysm modelJournal of Neurosurgery, 2004
- Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2002
- Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a moldJournal of Neurosurgery, 2001
- Prevalence and Risk of Rupture of Intracranial AneurysmsStroke, 1998
- Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flowsJournal of Magnetic Resonance Imaging, 1997
- An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI)Journal of Medical Engineering & Technology, 1991
- Evaluation of Magnetic Resonance Velocimetry for Steady FlowJournal of Biomechanical Engineering, 1990
- The measurement of blood density and its meaningBasic Research in Cardiology, 1989
- Quantitative Flow Measurement in Phase Contrast MR AngiographyJournal of Computer Assisted Tomography, 1988
- NMR rheotomography: Feasibility and clinical potentialMedical Physics, 1982