Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation
Open Access
- 22 April 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (5) , 958-966
- https://doi.org/10.1002/mrm.10148
Abstract
The presence of magnetic background field inhomogeneity (ΔB) may confound quantitative measures of cerebral venous blood volume (vCBV) and cerebral oxygen extraction fraction (MR_OEF) with T-based methods. The goal of this study was to correct its effect and obtain more accurate estimates of vCBV and MR_OEF. A 3D high-resolution gradient echo sequence was employed to obtain ΔB maps by two algorithms. The ΔB maps were then used to recover the signal loss in images acquired by a 2D multiecho gradient echo / spin echo sequence. Finally, both quantitative estimates of MR_OEF and vCBV were obtained from the ΔB- corrected 2D multiecho gradient echo / spin echo images. A total of 12 normal subjects were studied. An overestimated vCBV was observed in the brain (4.29 ± 0.78%) prior to ΔB correction, while the measured vCBV was substantially reduced after ΔB correction. Whole brain vCBV of 2.97 ± 0.44% and 2.68 ± 0.47% were obtained by the two different ΔB correction methods, in excellent agreement with the reported results in the literature. Furthermore, when MR_OEF was compared with and without ΔB correction, no significant differences (P = 0.467) were observed. The ability to simultaneously obtain vCBV and MR_OEF noninvasively may have profound clinical implications for the studies of cerebrovascular disease. Magn Reson Med 47:958–966, 2002.Keywords
This publication has 36 references indexed in Scilit:
- Theory and application of static field inhomogeneity effects in gradient‐echo imagingJournal of Magnetic Resonance Imaging, 1997
- Multi‐gradient echo with susceptibility inhomogeneity compensation (MGESIC): Demonstration of fMRI in the olfactory cortex at 3.0 TMagnetic Resonance in Medicine, 1997
- Quantitation of T2′ anisotropic effects on magnetic resonance bone mineral density measurementMagnetic Resonance in Medicine, 1997
- The Influence of Carbon Dioxide and Body Position on Near-Infrared Spectroscopic Assessment of Cerebral Hemoglobin Oxygen SaturationAnesthesia & Analgesia, 1996
- Validation in Volunteers of a Near-Infrared Spectroscope for Monitoring Brain Oxygenation In VivoAnesthesia & Analgesia, 1996
- Intravascular susceptibility contrast mechanisms in tissuesMagnetic Resonance in Medicine, 1994
- Reduction of susceptibility artifact in gradient‐echo imagingMagnetic Resonance in Medicine, 1992
- Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 TJournal of Magnetic Resonance Imaging, 1991
- Suggested Reference Values for Regional Blood Volumes in HumansHealth Physics, 1991
- Regional Cerebral Blood Volume and Hematocrit Measured in Normal Human Volunteers by Single-Photon Emission Computed TomographyJournal of Cerebral Blood Flow & Metabolism, 1985