Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
Top Cited Papers
- 17 March 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (4) , 983-995
- https://doi.org/10.1088/0031-9155/45/4/313
Abstract
Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft tissue, lung or bone. Therefore, for dose calculation algorithm comparisons, or to report dose to water or tissue contained within a bone matrix for example, a method to convert dose to the medium to dose to water is required. This conversion has been developed here by applying Bragg-Gray cavity theory. The dose ratio for 6 and 18 MV photon beams was determined by computing the average stopping power ratio for the primary electron spectrum in the transport media. For soft tissue, the difference between dose to medium and dose to water is approximately 1.0%, while for cortical bone the dose difference exceeds 10%. The variation in the dose ratio as a function of depth and position in the field indicates that for photon beams a single correction factor can be used for each particular material throughout the field for a given photon beam energy. The only exception to this would be for the clinically non-relevant dose to air. Pre-computed energy spectra for 60 Co to 24 MV are used to compute the dose ratios for these photon beams and to determine an effective energy for evaluation of the dose ratio.Keywords
This publication has 14 references indexed in Scilit:
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999
- A CT‐based Monte Carlo simulation tool for dosimetry planning and analysisMedical Physics, 1998
- Uncertainties in dosimetric data and beam calibrationInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Stopping power data for high-energy photon beamsPhysics in Medicine & Biology, 1986
- Energy and angular distributions of photons from medical linear acceleratorsMedical Physics, 1985
- A protocol for the determination of absorbed dose from high‐energy photon and electron beamsMedical Physics, 1983
- Water/air mass stopping power ratios for megavoltage photon and electron beamsPhysics in Medicine & Biology, 1978
- An ionization method for the absolute measurement of γ-ray energyProceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1936