Abstract
During multiple casualty incidents (MCI) emergency radiology departments have to deal with a large number of patients with suspected severe trauma within a short period of time. The aim of this study was to develop a suitable accelerated multislice computed tomography (MSCT) protocol to increase patient throughput for this kind of emergency situation. We presumed a scenario of 15 patients being admitted to the trauma service with suspicion of severe injuries after a MCI over a period of 2 h. An accelerated Triage MSCT protocol was developed and evaluated for MSCT scanner productivity (patients per hour) and time (minutes) needed for a total MSCT body workup using an anthropomorphic phantom. In addition, time (minutes) for transfer and preparation was measured. These timeframes were compared to a control group consisting of 144 single patients with multiple trauma undergoing standard MSCT according to our trauma room protocol. All MSCT studies were conducted using a 4-detector row scanner. (1) For the study group (Triage MSCT), average time for patient transfer and preparation was 2.9 min (2.5-4.3 min), mean CT examination time was 2.1 min (1.7-2.4 min); image reconstruction took 4.0 min (3.3-4.3 min). Total time in scanner room was 8.9 min (7.7-11.3 min), resulting in a maximal productivity of 6.7 patients per hour. Image transfer to the digital picture archive and communication system archive was completed after an average 9.5 min (8.9-10.8 min). (2) For the control group (single casualty MSCT), the mean time for patient transfer and preparation was 20.4 min (9.0-39.2 min), mean examination time was 6.0 min (3.1-11.3 min). Times for image reconstructions were not recorded in the patient series. Mean total time in scanner room was 25.3 min (11.0-72.4 min), resulting in a patient throughput of 2.4 patients per hour. MSCT has potential to serve as a powerful tool in triage of multiple casualty patients. The introduction of a Triage MSCT scanning protocol resulted in an increase of patient throughput per hour by a factor of almost 3.Keywords
This publication has 48 references indexed in Scilit:
- Dose Reduction in Multislice Computed TomographyJournal of Computer Assisted Tomography, 2005
- Disaster preparedness: It’s all about meCritical Care Medicine, 2005
- Principles of Mass Casualty Management Following Terrorist DisastersAnnals of Surgery, 2004
- Errors in a busy emergency departmentAnnals of Emergency Medicine, 2003
- Multislice CT (MSCT) in der Detektion und Klassifikation von Becken- und AzetabulumfrakturenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Multidetector CT: Detection of Active Hemorrhage in Patients with Blunt Abdominal TraumaAmerican Journal of Roentgenology, 2002
- Medical Management of Disasters and Mass Casualties From Terrorist Bombings: How Can We Cope?Published by Wolters Kluwer Health ,2002
- Radiologische Diagnostik beim Polytrauma: Interdisziplinäres ManagementRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- Ganzkörper-Spiral-CT zur Primärdiagnostik polytraumatisierter Patienten unter NotfallbedingungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- SECONDARY SURVEY FOLLOWING BLUNT TRAUMAPublished by Wolters Kluwer Health ,1993