Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies – with specific reference to the measurement of cardiac output
Top Cited Papers
Open Access
- 1 January 2009
- journal article
- review article
- Published by Springer Nature in Critical Care
- Vol. 13 (1) , 201
- https://doi.org/10.1186/cc7129
Abstract
Bland-Altman analysis is used for assessing agreement between two measurements of the same clinical variable. In the field of cardiac output monitoring, its results, in terms of bias and limits of agreement, are often difficult to interpret, leading clinicians to use a cutoff of 30% in the percentage error in order to decide whether a new technique may be considered a good alternative. This percentage error of ± 30% arises from the assumption that the commonly used reference technique, intermittent thermodilution, has a precision of ± 20% or less. The combination of two precisions of ± 20% equates to a total error of ± 28.3%, which is commonly rounded up to ± 30%. Thus, finding a percentage error of less than ± 30% should equate to the new tested technique having an error similar to the reference, which therefore should be acceptable. In a worked example in this paper, we discuss the limitations of this approach, in particular in regard to the situation in which the reference technique may be either more or less precise than would normally be expected. This can lead to inappropriate conclusions being drawn from data acquired in validation studies of new monitoring technologies. We conclude that it is not acceptable to present comparison studies quoting percentage error as an acceptability criteria without reporting the precision of the reference technique.Keywords
This publication has 19 references indexed in Scilit:
- Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgeryBritish Journal of Anaesthesia, 2007
- Retracted: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgeryBritish Journal of Anaesthesia, 2007
- Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurementsCritical Care, 2006
- Pulseco: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgeryThe Annals of Thoracic Surgery, 2002
- Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary techniqueBritish Journal of Anaesthesia, 2002
- Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilutionCritical Care Medicine, 1999
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Testing the safety of baxter continuous cardiac output monitoring systemJournal of Clinical Monitoring and Computing, 1996
- Comparing methods of measurement: why plotting difference against standard method is misleadingThe Lancet, 1995
- Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system.1994