Handheld Rectilinear Ion Trap Mass Spectrometer
- 5 August 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (17) , 5994-6002
- https://doi.org/10.1021/ac061144k
Abstract
A shoebox-sized, 10-kg, handheld mass spectrometer, Mini 10, based on a rectilinear ion trap mass analyzer has been designed, built, and characterized. This instrument has evolved from a decade-long experimental and simulation program in mass spectrometer miniaturization. The rectilinear ion trap has a simplified geometry and high trapping capacity, and when used with a miniature and ruggedized pumping system, it allows chemical analysis while the instrument is being carried. Compact electronics, including an air core RF drive coil, were developed to control the instrument and to record mass spectra. The instrument runs on battery power, consuming less than 70 W, similar to a laptop computer. Wired and wireless networking capabilities are implemented. The instrument gives unit resolution and a mass range of over m/z 500. Tandem mass spectrometry capabilities are implemented using collision-induced dissociation, and they are used to provide confirmation of chemical structure during in situ analysis. Continuous monitoring of air and solution samples is demonstrated, and a limit of detection of 50 ppb was obtained for toluene vapor in air and for an aqueous naphthalene solution using membrane sample introduction.Keywords
This publication has 21 references indexed in Scilit:
- Microfabricated Quadrupole Ion Trap for Mass Spectrometer ApplicationsPhysical Review Letters, 2006
- Atmospheric Pressure Ionization in a Miniature Mass SpectrometerAnalytical Chemistry, 2005
- Rectilinear Ion Trap: Concepts, Calculations, and Analytical Performance of a New Mass AnalyzerAnalytical Chemistry, 2004
- Characterization of a serial array of miniature cylindrical ion trap mass analyzersRapid Communications in Mass Spectrometry, 1999
- A Quadrupole Ion Trap with Cylindrical Geometry Operated in the Mass-Selective Instability ModeAnalytical Chemistry, 1998
- Miniature, high-resolution, quadrupole mass-spectrometer arrayReview of Scientific Instruments, 1997
- High-breakdown voltage Al 0.66 In 0.34 As 0.85 Sb 0.15 /In 0.75 Ga 0.25 As/InPheterostructure field-effect transistorsElectronics Letters, 1996
- High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10−9 to 10−2 TorrJournal of Vacuum Science & Technology A, 1996
- Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratiosInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Fourier transform ion cyclotron resonance spectroscopyChemical Physics Letters, 1974