Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: A dose-response study of protein concentration
Open Access
- 1 January 2000
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 71 (4) , 365-369
- https://doi.org/10.1080/000164700317393358
Abstract
Charnley's laboratory wear studies of non-gamma sterilized polytetrafluoroethylene (PTFE) and polyethylene (PE) found that the PTFE to PE wearrate ratio of 250:1 was much higher than the in-vivo wear ratio of 20:1. Tests of PTFE and PE in our laboratory showed a wear ratio of 150:1, using bovine serum as the lubricant and 190:1 with water as the lubricant. Our hypothesis was that the wear-rates of PTFE and PE cup materials were related to the concentration of protein in the serum. We studied the wear behavior of PTFE and PE cups in varied protein concentrations, using 4 femoral head sizes to validate the clinical range reported by Charnley. The PTFE wear-rates increased with increasing protein concentration and conversely, PE wear-rates decreased with increasing protein concentration. This inverse relationship made it possible to bring the wear ratio closer to the desired clinical wear ratio. We found that the clinically relevant PTFE/PE wear ratio corresponded to 3-10 mg/mL of protein in bovine serum.Keywords
This publication has 15 references indexed in Scilit:
- Low wear and friction in alumina/alumina total hip joints: A hip simulator studyActa Orthopaedica, 1998
- Electronic publishing- the next stepsThe Journal of Bone and Joint Surgery. British volume, 1997
- Charnley wear model for validation of hip simulators' ball diameter versus polytetrafluoroethylene and polyethylene wearProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- The Importance of Multidirectional Motion on the Wear of PolyethyleneProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditionsBiomaterials, 1996
- Wear of the polyethylene acetabular cup: The effect of head material, head diameter, and cup thickness studied with a hip simulatorActa Orthopaedica, 1995
- Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip jointsMedical Engineering & Physics, 1994
- Wear of polyethylene acetabular cups against alumina femoral heads: 5 prostheses compared in a hip simulator for 35 million walking cyclesActa Orthopaedica, 1993
- The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethyleneClinical Materials, 1993
- The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hipMedical & Biological Engineering & Computing, 1969