Evaluation of high‐field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discovery
- 18 June 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (14) , 2295-2300
- https://doi.org/10.1002/rcm.3093
Abstract
The potential of high‐field asymmetric waveform ion mobility spectrometry (FAIMS) coupled to nanoelectrospray ionization (nanoESI) as a method to improve sample throughput for bioanalysis in a discovery pharmaceutical setting was explored in this work. The ability of FAIMS to separate gas‐phase ions in the millisecond timescale was exploited to eliminate the need for liquid chromatography. Samples were introduced into the FAIMS electrodes/mass spectrometer using offline nanoESI at 20 nL/min and 1.5 kV. Signals were averaged for 30 s after which the next sample could be analyzed. The separation of simple mixtures, e.g., the removal of metabolite and endogenous interferences from parent drug, was demonstrated. Moreover, the application of nanoESI attenuated the ion suppression effects that normally plague conventional electrospray. On average, approximately two‐thirds of the neat sample signal intensity was preserved in extracted plasma samples. Standard curves were prepared for several compounds and linearity was obtained over approximately two to three orders of magnitude. This methodology was further tested with the analysis of plasma samples from a mouse pharmacokinetic study. Concentration values determined using nanoESI‐FAIMS were comparable to those determined using conventional LC/MS as demonstrated by percent differences of less than 30%. This work demonstrated the proof of concept that the combination of FAIMS and nanospray ionization can be a potentially useful tool to improve the throughput of discovery bioanalysis. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Rapid Separation and Quantitative Analysis of Peptides Using a New Nanoelectrospray- Differential Mobility Spectrometer−Mass Spectrometer SystemAnalytical Chemistry, 2006
- Simultaneous analysis of prostanoids using liquid chromatography/high‐field asymmetric waveform ion mobility spectrometry/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Ultra‐low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard‐free quantitative estimation of metabolite levels in drug discoveryRapid Communications in Mass Spectrometry, 2006
- High‐throughput quantification for a drug mixture in rat plasma – a comparison of Ultra Performance™ liquid chromatography/tandem mass spectrometry with high‐performance liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high-field asymmetric waveform ion mobility spectrometryRapid Communications in Mass Spectrometry, 2005
- High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometryJournal of Chromatography A, 2004
- Reduction of Signal Suppression Effects in ESI-MS Using a Nanosplitting DeviceAnalytical Chemistry, 2001
- High‐speed liquid chromatography/tandem mass spectrometry using a monolithic column for high‐throughput bioanalysisRapid Communications in Mass Spectrometry, 2001
- Rapid bioanalysis of vancomycin in serum and urine by high‐performance liquid chromatography tandem mass spectrometry using on‐line sample extraction and parallel analytical columnsRapid Communications in Mass Spectrometry, 2001
- Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass SpectrometryAnalytical Chemistry, 1999