Review article. To provide a detailed overview of current methods for intraoperative spinal navigation using image-guided surgical technology. The development of novel intraoperative navigational techniques has been an important advancement in the field of spine surgery. These techniques, commonly referred to as image-guided surgery (IGS), provide simultaneous, multiplanar views of spinal anatomy. They can be used for detailed preoperative planning and allow the spinal surgeon to track the position of surgical instruments in real time. IGS technology can increase the accuracy of spinal instrumentation procedures and improve patient safety. The relevant medical literature was reviewed, as was the authors' clinical and laboratory experience with intraoperative spinal navigation. Image-guided spinal instrumentation procedures in the cervical, thoracic, and lumbar spine have lower rates of screw misplacement than do those performed without image guidance. In a typical IGS spinal procedure, surgical instruments are tracked in the operating room, and their positions are superimposed onto preoperatively acquired computed tomography scans (CT-based image guidance) or intraoperatively acquired fluoroscopic images (virtual fluoroscopy). A new development, the combination of isocentric C-arm fluoroscopy with computer-assisted image guidance, allows the C-arm to create intraoperative CT images that can be used for image-guided navigation without the need for a surgeon-dependent registration step. Each of these technologies has distinct advantages and limitations. Intraoperative spinal navigation has advanced rapidly in recent years, beneficially affecting a variety of surgical procedures. Future technological developments will widen its clinical application and minimize its shortcomings.Keywords
This publication has 22 references indexed in Scilit:
- Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw InsertionSpine, 2000
- Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patientsEuropean Spine Journal, 2000
- Clinical Relevance of Accuracy of Pedicle Screw PlacementSpine, 1998
- Pedicle Screw Placement Using Image Guided TechniquesClinical Orthopaedics and Related Research, 1998
- Frameless stereotactic guided neurosurgery: Clinical experience with an infrared based pointer device navigation systemActa Neurochirurgica, 1997
- Accuracy of Computer-Assisted Pedicle Screw PlacementSpine, 1997
- Accuracy of Pedicle Screw Placement in Lumbar VertebraeSpine, 1996
- Image-Guided Spine SurgeryNeurosurgery Clinics of North America, 1996
- Exposure of the orthopaedic surgeon to radiation.Journal of Bone and Joint Surgery, 1993
- Extracranial Application of the Frameless Stereotactic Operating MicroscopeNeurosurgery, 1993