Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing
- 1 April 2004
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 218 (4) , 261-270
- https://doi.org/10.1243/0954411041561045
Abstract
The elastohydrodynamic lubrication (EHL) analysis was carried out in this study for a 28 mm diameter metal-on-metal hip prosthesis employing a metallic cup with an ultra-high molecular weight polyethylene (UHMWPE) backing under a simple steady state rotation representing the flexion/extension during walking. Both Reynolds and elasticity equations were coupled and solved numerically by the finite difference method. The elastic deformation was determined by means of the fast Fourier transform (FFT) technique using the displacement coefficients obtained from the finite element method. Excellent agreement of the predicted elastic deformation was obtained between the FFT technique and the conventional direct summation method. The number of grid points used in the lubrication analysis was found to be important in predicting accurate film thicknesses, particularly at low viscosities representative of physiological lubricants. The effect of the clearance between the femoral head and the acetabular cup on the predicted lubricant film thickness was shown to be significant, while the effect of load was found to be negligible. Overall, the UHMWPE backing was found not only to reduce the contact pressure as identified in a previous study by the authors (Liu et al., 2003) but also significantly to increase the lubricant film thickness for the 28mm diameter metal-on-metal hip implant, as compared with a metallic mono-block cup.Keywords
This publication has 20 references indexed in Scilit:
- Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backingProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2003
- Effects of Metal-Inlay Thickness in Polyethylene Cups With Metal-on-Metal BearingsPublished by Wolters Kluwer Health ,2002
- Contact mechanics of a novel metal-on-metal total hip replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- In vitro comparison of the two hard-hard articulations for total hip replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal ArticulationJournal of Bone and Joint Surgery, 2000
- Wear and Lubrication of Metal-on-Metal Hip ImplantsClinical Orthopaedics and Related Research, 1999
- Evolution and future of surface replacement of the hipJournal of Orthopaedic Science, 1998
- In Vivo Wear of 3 Types of Metal on Metal Hip Prostheses During 2 Decades of UseClinical Orthopaedics and Related Research, 1996
- Metal on Metal Bearings in Hip ArthroplastyClinical Orthopaedics and Related Research, 1996