Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation--a prospective evaluation
- 3 September 2014
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (2) , 225-231
- https://doi.org/10.1093/europace/euu215
Abstract
Aims In the setting of paroxysmal atrial fibrillation (AF), there are no available data comparing the mid-term outcome of patients undergoing pulmonary vein isolation (PVI) catheter ablation using contact-force (CF)-guided radiofrequency (RF) vs. second-generation balloon cryotherapy. Methods and results Prospective single-centre evaluation, carried out from March 2011 to February 2013, comparing CF radiofrequency (Thermocool® SmartTouch™, Biosense Webster, Inc.) (CF group) with cryoballoon ablation (Arctic Front Advance™ 28 mm cryoballoon, Medtronic, Inc.) (CB group), in regards to procedural safety and efficacy, as well as recurrence at 12 months. Overall, 150 consecutive patients were enrolled (75 in each group). The characteristics of patients of both the groups were similar (61.2 ± 9.9 years, women 25.3%, mean AF duration 4.1 ± 4.0 years, mean CHA2DS2-VASc score 1.4 ± 1.3, mean HAS-BLED 1.4 ± 0.6). Duration of the procedure was significantly lower in the CF group (110.7 ± 32.5 vs. 134.5 ± 48.3 min, P = 0.001), with a lower duration of fluoroscopy (21.5 ± 8.5 vs. 25.3 ± 9.9 min, P = 0.017) and X-ray exposure (4748 ± 2411 cGy cm² vs. 7734 ± 5361 cGy cm², P = 0.001). In contrast, no significant difference was found regarding significant procedural complication (2.7 vs. 1.3% in CF and CB groups, respectively; P = 0.56), and PVI was eventually achieved in all cases. At 12 months, AF recurrence occurred in 11 patients (14.7%) in the CB group and in 9 patients (12.0%) in the CF group (HR = 1.20 95% CI 0.50–2.90; log rank P = 0.682). Conclusions Our preliminary findings suggest that CF-guided radiofrequency and cryotherapy present very similar performances in the setting of paroxysmal AF catheter ablation.Keywords
This publication has 32 references indexed in Scilit:
- Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesionsEP Europace, 2014
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEP Europace, 2012
- Venice Chart International Consensus Document on Atrial Fibrillation Ablation: 2011 UpdateJournal of Cardiovascular Electrophysiology, 2012
- Long-Term Results of Catheter Ablation in Paroxysmal Atrial FibrillationCirculation, 2010
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010
- Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force‐Sensing CatheterJournal of Cardiovascular Electrophysiology, 2010
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein ConductionCirculation, 2005
- Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary VeinsCirculation, 2005
- Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy DeliveryJournal of Cardiovascular Electrophysiology, 1991