Real‐Time Contact Force Sensing for Pulmonary Vein Isolation in the Setting of Paroxysmal Atrial Fibrillation: Procedural and 1‐Year Results
- 8 October 2013
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 25 (2) , 130-137
- https://doi.org/10.1111/jce.12303
Abstract
Introduction The additional benefit of contact force (CF) technology during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) to improve mid‐term clinical outcome is unclear. Methods and Results Eligible patients with symptomatic paroxysmal AF were enrolled in this prospective trial, comparing circular antral catheter ablation (guided by Carto 3 System, Biosense Webster) using either a new open‐irrigated CF catheter (SmartTouch Thermocool, Biosense Webster) (CF group) or a non‐CF open‐irrigated catheter (EZ Steer Thermocool, Biosense Webster) (control group). Overall, 30 patients were enrolled in each group, with a standardized 12‐month follow‐up, free of antiarrhythmic therapy. Demographic, cardiovascular and anatomic characteristics were similar in both groups. Though complete PVI was eventually achieved in all cases in both groups, success using an exclusive anatomic approach was 80.0% in CF group versus 36.7% in control group (P < 0.0001). CF use was associated with significant reductions in fluoroscopy exposure (P < 0.01) and radiofrequency time (P = 0.01). The incidence rates of AF recurrence were 10.5% (95% CI, 1.38–22.4) in the CF group, and 35.9% (95% CI, 12.4–59.4) in the control group (log rank test, P = 0.04). After adjustment on potential confounders, the use of CF catheter was found to be associated with a lower AF recurrence (OR 0.18, 95% CI 0.04–0.94, P = 0.04). Conclusion Our findings suggest a potential benefit of real‐time CF sensing technology, in reducing AF recurrence during the first year after PVI.Keywords
This publication has 29 references indexed in Scilit:
- Long‐term Outcomes of Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐analysisJournal of the American Heart Association, 2013
- Contact force–controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substratesHeart Rhythm, 2012
- Procedural Complications, Rehospitalizations, and Repeat Procedures After Catheter Ablation for Atrial FibrillationJournal of the American College of Cardiology, 2012
- Natural History and Long-Term Outcomes of Ablated Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2011
- Long-Term Results of Catheter Ablation in Paroxysmal Atrial FibrillationCirculation, 2010
- Catheter tip force required for mechanical perforation of porcine cardiac chambersEP Europace, 2010
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010
- Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force‐Sensing CatheterJournal of Cardiovascular Electrophysiology, 2010
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- A Systematical Analysis of In Vivo Contact Forces on Virtual Catheter Tip/Tissue Surface Contact during Cardiac Mapping and InterventionJournal of Cardiovascular Electrophysiology, 2008