Mechanistic inquiry into decrease in probability of defibrillation success with increase in complexity of preshock reentrant activity
Open Access
- 1 March 2004
- journal article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 286 (3) , H909-H917
- https://doi.org/10.1152/ajpheart.00492.2003
Abstract
Energy requirements for successful antiarrhythmia shocks are arrhythmia specific. However, it remains unclear why the probability of shock success decreases with increasing arrhythmia complexity. The goal of this research was to determine whether a diminished probability of shock success results from an increased number of functional reentrant circuits in the myocardium, and if so, to identify the responsible mechanisms. To achieve this goal, we assessed shock efficacy in a bidomain defibrillation model of a 4-mm-thick slice of canine ventricles. Shocks were applied between a right ventricular cathode and a distant anode to terminate either a single scroll wave (SSW) or multiple scroll waves (MSWs). From the 160 simulations conducted, dose-response curves were constructed for shocks given to SSWs and MSWs. The shock strength that yielded a 50% probability of success (ED50) for SSWs was found to be 13% less than that for MSWs, which indicates that a larger number of functional reentries results in an increased defibrillation threshold. The results also demonstrate that an isoelectric window exists after both failed and successful shocks; however, shocks of strength near the ED50 value that were given to SSWs resulted in 16.3% longer isoelectric window durations than the same shocks delivered to MSWs. Mechanistic inquiry into these findings reveals that the two main factors underlying the observed relationships are 1 ) smaller virtual electrode polarizations in the tissue depth, and 2 ) differences in preshock tissue state. As a result of these factors, intramural excitable pathways leading to delayed breakthrough on the surface were formed earlier after shocks given to MSWs compared with SSWs and thus resulted in a lower defibrillation threshold for shocks given to SSWs.Keywords
This publication has 28 references indexed in Scilit:
- Virtual Electrode‐Induced Positive and Negative Graded Responses:Journal of Cardiovascular Electrophysiology, 2003
- Three‐Dimensional Mapping of Earliest Activation after Near‐Threshold Ventricular Defibrillation ShocksJournal of Cardiovascular Electrophysiology, 2003
- Mechanism of Ventricular Defibrillation for Near-Defibrillation Threshold ShocksCirculation, 2001
- Optical Mapping of Ventricular Defibrillation in Isolated Swine Right VentriclesCirculation, 2001
- Success and Failure of the Defibrillation Shock:Journal of Cardiovascular Electrophysiology, 2000
- Virtual Electrode–Induced Phase SingularityCirculation Research, 1998
- Epicardial Sock Mapping Following Monophasic and Biphasic Shocks of Equal Voltage with an Endocardial Lead SystemJournal of Cardiovascular Electrophysiology, 1996
- Comparison of activation during ventricular fibrillation and following unsuccessful defibrillation shocks in open-chest dogs.Circulation Research, 1990
- Activation during ventricular defibrillation in open-chest dogs. Evidence of complete cessation and regeneration of ventricular fibrillation after unsuccessful shocks.Journal of Clinical Investigation, 1986
- Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration.Circulation, 1984