Thermally stimulated current spectroscopy: Experimental techniques for the investigation of silicon detectors
- 1 April 1993
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 64 (4) , 932-936
- https://doi.org/10.1063/1.1144145
Abstract
Radiation damage of silicon detectors can be investigated by means of several techniques. In a high‐luminosity environment the thermally stimulated current (TSC) spectroscopy proves to be a good experimental method in order to analyze the deep defects induced by irradiation. Two different experimental systems for TSC spectroscopy, developed at the Energy Engineering Department of Florence, are examined in detail. The two systems differ in the cryogenic agent used to cool the silicon detectors: the first one utilizes a helium‐gas closed‐cycle Gifford–McMahon two‐stage cryogenerator; the second one utilizes the helium vapors present inside a liquid helium Dewar. In the two systems two different heating procedures are used in order to perform the thermal scans necessary to carry on the TSC measurements: in the former system an electric heater performs the thermal scan, while in the latter one the heating process is achieved utilizing the temperature variation of the helium vapors inside the Dewar as a function of the height over the surface of the boiling helium. The main advantage of the electric heater is the possibility of obtaining heating rates β as high as 2.0 K/s, while the helium vapors ensure an excellent temperature matching between the temperature sensor and the sample (with the drawback of lower heating rates). The two methods used to get information by means of TSC spectroscopy, (variation of β and delayed heating) are briefly described together with an evaluation of the sensitivity of the measurement (no difference has been made between the two systems because the use of a different cryogenic agent does not affect sensitivity). Both systems proved satisfactory, even if the ease of operation of the helium gas makes it preferable in the temperature range examined by our measurements (120–200 K).Keywords
This publication has 11 references indexed in Scilit:
- Results on radiation hardness of silicon detectors up to neutron fluences of 1015 n/cm2Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
- Effects of fast neutron radiation on the electrical properties of silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- Deep-level transient spectroscopy measurements of majority carrier traps in neutron irradiated n-type silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Trapping center parameters in indium selenide single crystals by thermally stimulated current measurementsJournal of Applied Physics, 1983
- TSC defect level in silicon produced by irradiation with muons of GeV-energyRadiation Effects, 1976
- Thermally stimulated current measurements on silicon junctions produced by implantation of low energy boron ionsSolid-State Electronics, 1974
- Deep-level transient spectroscopy: A new method to characterize traps in semiconductorsJournal of Applied Physics, 1974
- Impurity centers in PN junctions determined from shifts in the thermally stimulated current and capacitance response with heating rateSolid-State Electronics, 1972
- On the determination of deep level center energy and concentration by thermally stimulated conductivity measurements using reverse-biased p-n junctionsSolid-State Electronics, 1971
- Determination of deep centers in silicon by thermally stimulated conductivity measurementsSolid-State Electronics, 1969